Set time remotely windows 7




















The situation is that I have one server on a remote LAN which has the wrong system date - it thinks it's yesterday. Actually, no I don't feel stupid That command will set the local computer's time to yesterday, not the other way around. I need the "opposite" of that command. You could do it with "psexec" from sysinternals, part of the pstools suite.

It gives you remote access to the server cmd line. Fill in your details below or click an icon to log in:. Email required Address never made public. Name required. Search for:. Create a free website or blog at WordPress. Follow Following. Sign me up. This thread is locked. You can follow the question or vote as helpful, but you cannot reply to this thread.

I have the same question 5. Report abuse. Details required :. If the time service adjusts the local clock by setting the clock directly, and the time correction is more than this value, then the time service logs an audit event. UpdateInterval All versions Specifies the number of clock ticks between phase correction adjustments. The default value for domain members is 30, The default value for stand-alone clients and servers is , Note Zero is not a valid value for the UpdateInterval registry entry.

The default value on stand-alone clients and servers is 1. The default value on stand-alone clients and servers is 0x1. The NtpServer is a time server that responds to client time requests on the network by returning time samples that are useful for synchronizing the local clock. LargeSampleSkew All versions Specifies the large sample skew for logging, in seconds. Events will be logged for this setting only when EventLogFlags is explicitly configured for 0x2 large sample skew. The default value on domain members is 3.

The default value on stand-alone clients and servers is 3. ResolvePeerBackOffMaxTimes All versions Specifies the maximum number of times to double the wait interval when repeated attempts to locate a peer to synchronize with fail.

A value of zero means that the wait interval is always the minimum. The default value on domain members is 7. ResolvePeerBackoffMinutes All versions Specifies the initial interval to wait, in minutes, before attempting to locate a peer to synchronize with. SpecialPollInterval All versions Specifies the special poll interval, in seconds, for manual peers.

When the SpecialInterval 0x1 flag is enabled, W32Time uses this poll interval instead of a poll interval determined by the operating system. The default value on domain members is 3, The default value on stand-alone clients and servers is , It contains reserved data that is used by the Windows operating system. It specifies the time, in seconds, before W32Time will resynchronize after the computer has restarted.

Any changes to this setting can cause unpredictable results. The default value on both domain members and on stand-alone clients and servers is left blank. The following registry entries are not a part of the W32Time default configuration but can be added to the registry to obtain enhanced logging capabilities. By default, the Windows Time service logs an event every time that it switches to a new time source.

These are the global Group Policy settings and default values for the Windows Time service. Skip to main content. This browser is no longer supported. Download Microsoft Edge More info. Contents Exit focus mode. Is this page helpful? Please rate your experience Yes No. Any additional feedback? Caution Don't use the Net time command to configure or set a computer's clock time when the Windows Time service is running.

Note If you have a computer with multiple network adapters is multi-homed , you cannot enable the Windows Time service based on a network adapter. Important Windows Server has improved the time synchronization algorithms to align with RFC specifications. Note In this case, if you want to set the clock back slowly, you would also have to adjust the values of PhaseCorrectRate or UpdateInterval in the registry to make sure that the equation result is TRUE. Note When you remove a Group Policy setting, Windows removes the corresponding entry from the policy area of the registry.

Warning This information is provided as a reference for use in troubleshooting and validation. Note Some of the parameters in the registry are measured in clock ticks and some are measured in seconds. Ticks Property. Submit and view feedback for This product This page. View all page feedback.

In this article. Registers the Windows Time service to run as a service and adds its default configuration information to the registry. Unregisters the Windows Time service and removes all of its configuration information from the registry. Monitors the Windows Time service.

Converts a Windows NT system time measured in 10 -7 -second intervals starting from 0h 1-Jan into a readable format. Converts an NTP time measured in 2 -second intervals starting from 0h 1-Jan into a readable format. Tells a computer that it should resynchronize its clock as soon as possible, throwing out all accumulated error statistics.

Displays a strip chart of the offset between this computer and another computer. Displays the values associated with a given registry key. Displays the computer's Windows Time service information. Enables or disables the local computer Windows Time service private log.

Controls whether this computer is marked as a reliable time server. A computer is not marked as reliable unless it is also marked as a time server. Not a time server 0x Always time server 0x Automatic time server 0x Always-reliable time server 0x Automatic reliable time server The default value for domain members is Controls whether or not the chaining mechanism is disabled.